5.2.5 Private Managed Objects
MIBs for Contemporary Controls 1.3.6.1.4.1.17384
Switch Family 1.3.6.1.4.1.17384.1
Switch Series 1.3.6.1.4.1.17384.1.1
oid = “1.3.6.1.4.1.17384.1.1.1.0
temperature: Indicates the internal temperature of the switch in degrees Celsius
Type: string
Access: read-only
5.2.5.1 Relay Group 1.3.6.1.4.1.17384.1.1.2
oid = "1.3.6.1.4.1.17384.1.1.2.1.0"
switchFaultStatus: The fault status of this switch
Type: integer
1 = fault has occurred
2 = no fault has occurred
Access: read-only
5.2.5.1.1 Fault Table faultTable’ 1.3.6.1.4.1.17384.1.1.2.2
oid = "1.3.6.1.4.1.17384.1.1.2.2.1.ifIndex"
portMonitoringFaultStatus: Fault status for each port
Type: integer
1 = fault has occurred
2 = no fault has occurred
Access: read-only
5.2.5.2 RapidRing Group 1.3.6.1.4.1.17384.1.1.3
oid = “1.3.6.1.4.1.17384.1.1.3.1.0”
ringEnableStatus: The RapidRing is enabled or disabled
Type: integer
1 = RapidRing is enabled
2 = RapidRing is disabled
oid = “1.3.6.1.4.1.17384.1.1.3.2.0”
switchMode: The switch is a Master or a Slave
Type: integer
1 = Master
2 = Slave
oid = “1.3.6.1.4.1.17384.1.1.3.3.0”
ringID: The group number of the RapidRing
Type: integer
1 = group number 1
2 = group number 2
oid = “1.3.6.1.4.1.17384.1.1.3.4.0”
networkStatus: The network topology
Type: integer
1 = Ring Not Available (because RapidRing is not enabled)
2 = Ring Complete
3 = Ring Incomplete