AI-SRVR
ARCNET Server to Ethernet Client
Software Manual
# TD000200-0MC
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - AI-SRVR

AI-SRVR ARCNET Server to Ethernet Client Software Manual # TD000200-0MC

Strona 2

TD000200-0MC 10 4.1.4.5 Web Browser Access (Read Only) Although the AI-SRVR must be configured via either its console port (Section 4.1.4.2) or via a

Strona 3 - 1 Table of Contents

TD000200-0MC 11 4.2 AI-SRVR Function 4.2.1 AI-SRVR Statistics Screen (Read Only) When the AI-SRVR Function is initially invoked, the default AI-SRVR S

Strona 4 - 3 Introduction

TD000200-0MC 12 The screen of Figure 6 offers three case-insensitive options: R forces an immediate refresh of the screen. Otherwise, the screen ref

Strona 5 - 3.1 Product Images

TD000200-0MC 13 All fields in the centre and right columns of Figure 7 require numerical values: IP Addr is 192.168.92.68 by default. Defining a new

Strona 6 - 4 Operation

TD000200-0MC 14 Then, the Hostname field should be modified if desired. Next, the BRIDGE fields should be configured. The Node ID can be any value fro

Strona 7 - 4.1.4 Access Options

TD000200-0MC 15 Keepalive Probes is the number of retransmissions to be carried out before declaring that the remote end is not available. TCP Retries

Strona 8

TD000200-0MC 16 4.3 AI-PROXY Function The AI-SRVR offers a function called “AI-PROXY”. This function allows an ARCNET node in one LAN to communicate

Strona 9

TD000200-0MC 17 The AI-SRVR-1 and the AI-SRVR-8 can be used together — for example, to add a remote ARCNET node to an eight-node ARCNET system as show

Strona 10

TD000200-0MC 18 4.3.1 AI-PROXY Statistics Screen (Read Only) A sample AI-PROXY Statistics screen appears in Figure 11. The 3 upper ETHERNET fields an

Strona 11 - 4.2 AI-SRVR Function

TD000200-0MC 19 4.3.2 AI-PROXY Configuration The AI-PROXY configuration screen differs from that of the AI-SRVR in that five fields have been deleted

Strona 12 - 4.2.2 AI-SRVR Configuration

TD000200-0MC 2 Trademarks BASautomation, Contemporary Controls and CTRLink are registered trademarks of Contemporary Control Systems, Inc. BACnet is a

Strona 13 - EXPLANATION OF EACH FIELD

TD000200-0MC 20 EXAMPLE: Figure 13 shows how (using sample values) the fields of an AI-SRVR-8/CXB might be configured in AI-PROXY mode. Only those

Strona 14

TD000200-0MC 3 1 Table of Contents 1 TABLE OF CONTENTS ... 3

Strona 15

TD000200-0MC 4 2 History 2/1/2005 Initial Release 7/1/2006 Expanded LED and Proxy functionality 7/1/2014 Added TCP timeouts, Hostname and expanded Se

Strona 16 - 4.3 AI-PROXY Function

TD000200-0MC 5 AI-SRVR-1/485D AI-SRVR-8/485D AI-SRVR-1/485X AI-SRVR-8/485X AI-SRVR-1/CXB AI-SRVR-8/CXB AI-SRVR-1/TB5 AI-SRVR-8/TB5 3.1 Product Image

Strona 17

TD000200-0MC 6 4 Operation 4.1 General Considerations Configuration is accomplished while the AI-SRVR is connected to a suitable device, either a com

Strona 18

TD000200-0MC 7 4.1.4 Access Options The AI-SRVR can be accessed through its Ethernet port or its console (serial) port. Initially, the unit must be c

Strona 19 - 4.3.2 AI-PROXY Configuration

TD000200-0MC 8 A Telnet session requires a login procedure as displayed in Figure 2. The default login string is “root” and it is echoed on screen.

Strona 20

TD000200-0MC 9 For initial configuration, the computer chosen for the procedure should temporarily have its IP address modified as shown in Figure 4 —